Metronic logo
Metronic logo

Flow computers

FP4

FP4 is a modern, versatile and precise flow meter with internal data logging. Equipped with two analogue inputs (RTD, 4-20mA, voltage or resistive output transducers) and two PULS inputs (frequency measurement, pulse counting, binary signal tracking and recording), can measure flow and other values, such as temperature and humidity. In addition FP4 has two math channels and two totalizers assigned to each of the six available channels. All this in a device with a 4-inch touch screen.

Flow totalizer with data recording

• 2 analog inputs
• 2 PULS inputs
• 2 math channels
• 4-20mA analog output
• 4 solid state relays
• USB port on front panel
• Ethernet port (Modbus TCP protocol, server www)
• RS-485 port (Modbus RTU protocol)
E-mail notifications, information about alarms, cycilc reports with totalizers value
• 4” Touch screen LCD
• Internal memory 2 GB

2 ANALOG INPUTS

Independent setup for input sensors
•  Transducers with 4-20mA (with optional power supply from device) or 0-20mA current loop output
•  RTD sensors (Pt100, Pt200, Pt500, Pt1000)
•  Transducers with 0…2500 Ω resistance output
•  Transducers with –1 V…+1 V or –10 V…+10 V voltage output

2 PULS INPUTS

• Frequency measurement in range 0,01 Hz … 10 kHz
• Counting pulses
• Tracking and recording of binary signal (shorting or disconnecting)

ANALOG OUTPUT

• Retransmission of one of the channels as a 4-20mA current loop output signal

TOTALIZERS

• For each input there are available two totalizers L1 and L2
• Totalizers can be reset manually or they can work automatically: daily ,weekly or monthly
• Totalizers T1 and T2 counting the operation time of totalizers
• Frequency of archiving, for counters, from 1 min to 24h

4 ALARM AND CONTROL SYSTEM

• 4 solid state relays 0,1 A / 60 V
• 2 alarm and control thresholds for each channel

RECORDING MEASUREMENT RESULT

• Recording data to internal 2GB memory, local access to recorded data through USB port on the front panel
• Data recording rate between 2 s and 24 h; two recording frequencies toggled upon exceeding the set alarm thresholds

INTENDED USE

• Measurement of flow and other quantities, e.g. temperature, humidity, pressure
• Operation in dispersed measurement systems with local readings of measurement results
• Grocery, steel, metallurgical, glass-making industry, warehouse and production line control

 

This product is CE marked.
Declarations of Conformity are available on request.

Front panel (FP4, FP4W)
Type of display

 

LCD TFT 4” 800 px X 480 px

LED backlight

Display size 86.4 mm X 52.5 mm
Keyboard resistive touch panel
Additional indication LED RGB
USB Port – front panel (FP4, FP4W)
Version USB 2.0 (with limited functionality, for connection of FLASH storage)
Connector type USB standard ‘A’ type socket
Files system FAT16, FAT32(1)
(1)Compatibility of all USB memory devices is not guaranteed.
Ethernet Port (FP4, FP4W)
Interface 10/100Base-T Ethernet
Connector type RJ-45
Transmission protocol Server WWW, Modbus TCP

ICMP (ping)

Number of connections opened simultaneously Max 4
RS-485 Serial Port (FP4, FP4W)
Signals output on terminal block A(+), B(-)
Galvanic isolation None
Maximum load 32 receivers/transmitters
Transmission protocol Modbus RTU Slave
Transmission rate 1.2, 2.4, 4.8, 9.6, 19.2, 38.4, 57.6, 115.2 kbps
Parity control Even, Odd, None
Frame 1 start bit, 8 data bits, 1 stop bit
Maximum length of line 1200 m
Internal terminating resistor Vcc-A(+)-B(-)-G: 390 Ω – 220 Ω – 390 Ω

(activated by DIP-switches)

Maximum differntial voltage A(+), B(-) -7 .. +12 V
Minimum output signal of transmitter 1.5 V (at RL= 54 W)
Minimum sensitivity of receiver 200 mV / RIN= 12 kW
Minimum impedance of data transmission line 54 W
Short-circuit/thermal protection Yes/Yes
Internal data memory (FP4, FP4W)
Memory type Flash
Capacity 2 GB
Estimated recording time for recording speed every 2 s for 6 measuring channels ca. 2 years
Supply (FP4)
Supply voltage 24 VDC (20 .. 30 VDC)
Maximum power consumption 6 W (typically 4 W)
Security The internal delay fuse 3.15 A, the exchange only by the service company
Supply (FP4W)
Supply voltage 100 .. 240 VAC 50/60 Hz or 24 VDC (20 .. 30 VDC)
Maximum power consumption ·  for 100 .. 240 VAC 50/60 Hz power supply:

8 W (typically 6 W)

·  for 24 VDC (20 .. 30 VDC) power supply:

6 W (typically 4 W)

Security The internal delay fuse 3.15 A, the exchange only by the service company
Output 24 V OUT (FP4W)
Output voltage (on 24 V OUT) unregulated 18 .. 26 VDC
Maximum load current (on 24 V OUT) 100 mA
Electrical connections (FP4)
Type screw terminal connectors
Wire cross section solid and flexible 0.14 .. 1.5 mm2

flexible with bootlace ferrule 0.25 .. 1.5 mm2

AWG 30/14

Electrical connections (FP4W)
Type spring type terminal block
Wire cross section ·  supply 230 VAC: 0.2 .. 2.5 mm2

·  others: 0.2 .. 1.5 mm2

Cable glands ·  supply: one M16 cable  gland,  cable diameter:
5 .. 10 mm·  I/O signals: three M20 cable glands, cable diameter: 8 .. 13 mm·  Ethernet: one M20 cable gland,  cable diameter: 6 mm (the possibility of installing a cable with an RJ-45 connector)
Mechanical Dimensions – enclosure (FP4)
Enclosure type panel mount, nonflammable plastic material „Noryl”
Dimensions with connectors (w X h X d) 144 mm X 72 mm X 127 mm
Dimensions of panel cut-out (w X h) 138+1 mm X 68+0.7 mm
Maximum panel thickness 5 mm
Weight 0.5 kg
Protection class IP30 on front panel side

IP30 on rear panel side

Mechanical Dimensions – enclosure (FP4W)
Enclosure type Wall mount, polycarbonate material
Dimensions (w X h X d) ·  without cable glands:

213 mm x 185 mm x 102 mm

·  with cable glands:

213 mm x 215 mm x 102 mm

Weight c.a. 0.8 kg
Protection class IP54
Environmental conditions (FP4, FP4W)
Ambient temperature ·  FP4: 0 .. +50 °C

·  FP4W: -20 .. +50 °C

Relative humidity 5 .. 95% (without steam condensation)
Maximum altitude <2000 m above sea level
Storage temperature -30 .. +70 °C
Degree of pollution PD2
EMC EMC Directive 2014/30/EU

EN 61326-1:2013 Table 2 (immunity)

EN 61326-1:2013 Class A (emission)

RoHS RoHS Directive 2011/65/EU
Installation location ·  FP4: Indoor only

·  FP4W: Indoor or outdoor(2)

(2)If additional protection against atmospheric precipitation is provided (roofing), the device can be installed outdoor.
ANALOGUE INPUTS (FP4, FP4W)
Number of inputs 2 (input type (0/4-20mA/RTD/U) configurable by jumpers inside the device)
Update rate 0.5 s/display every 1 s
Low-pass digital filter (damping filter)(3) A time constant programmed in the range 2 .. 60 s
Galvanic isolation between inputs None
Galvanic isolation from the other circuits Functional, 250 VAC
Maximum input voltage ±30 VDC between terminals A(I+), B(I-)
Configuration: 0/4-20mA input(4)
Measurement range 0 .. 22 mA
Input resistance <100 Ω
Initial accuracy (Ta=+25 °C) ±0.1% of range (typically ±0.05% of range)
Conversion characteristic Linear or User
Transducers powered from recorder 24 VDC (+10/-20%), 24 mA (current-limited polymer fuse)
(4)The device is delivered in the 0/4-20mA configuration.
Configuration: R/RTD input
Sensor type ·  Resistive (refer the table below)

·  Linear resistance

Sensor connection type 2-wire
Sensor current 420 μA
Wire resistance compensation in the 2-wire connection User programmed in the range of -99 .. +99 Ω
Resistance of wires (to the sensor) max 50 Ω
Transducer resistance range 0 .. 2700 Ω
Initial accuracy (Ta=+25 °C) ±0.5 Ω (typically ±0.3 Ω)
Conversion characteristic for R Linear, User or sensors
RTD sensor type, range and accuracy Refer the table below
Configuration: U (±10 V) input
Voltage range -10 .. +10 V
Input resistance >10 kΩ
Conversion characteristic (for U) Linear or User
Initial accuracy (Ta=+25 °C) ±0.5% of range
PULS TYPE INPUTS (FP4, FP4W)
Number of inputs 2
Measurement range ·  0.01 Hz .. 10 kHz, additional filter disabled

·  0.01 Hz .. 1 kHz, additional filter enabled

Minimum pulse width ·  50 μs, additional filter disabled

·  0.5 ms, additional filter enabled

Maximum input voltage ±30 VDC (between terminals F+ and F-)
Frequency measurement
Conversion characteristic Linear or User
Initial accuracy (Ta=+25 °C) 0.05% * f ±0.1 Hz
Pulse counting
Conversion characteristic Linear
Measuring range 0 .. 10 kHz
Initial accuracy (Ta=+25 °C) 0.05% * f ±0.1 Hz

(without losing pulses in the counters)

Configuration: OC/contact(5)
Open contact voltage ca. 4.3 V
Short circuit current ca. 4.3 mA
Switch on/off threshold ca. 2.4 V / 2.6 V
Maximum short circuit resistance 100 Ω
(5)The device is delivered in the OC/contact configuration, with the additional filtering capacitor disconnected.
Configuration: current input NAMUR
Input resistance 1.5 kΩ
Switch on/off threshold ca. 1.6 mA / 1.8 mA
Configuration: current input EH
Input resistance 200 Ω
Switch on/off threshold ca. 11 mA / 13 mA
Configuration: voltage input
Input resistance >10 kΩ
Switch on/off threshold ca. 2.4 V / 2.6 V
Maximum input voltage ±30 VDC
RELAY OUTPUTS (FP4, FP4W)
Number of outputs 4
Outputs type Solid state relays
Maximum voltage 60 V AC/DC
Maximum load current 0.1 A
ANALOGUE OUTPUT 4-20mA (FP4, FP4W)
Output signal 4-20 mA (3.6 .. 22 mA)
Current loop supply no (external supply required)
Maximum voltage between I+ and I- 28 VDC
Minimum supply current loop voltage 9 VDC (RL=0 Ω)
Loop resistance (RL) 0 .. 500 Ω
Accuracy 0.2%
Galvanic isolation to supply voltage Functional, 250 VAC

Software for analysis, visualization and archiving of measurement results.
See more Zobacz produkt

Software allows you to read settings files stored by the instrument, modify settings, save to file, and program the instrument via a USB memory stick. Software also allows you to create new settings files for the instruments
See more Zobacz produkt

Software mLog enable reading, visualization and archiving data from devices and transducers with RS485 port (Modbus RTU protocol) or Ethernet port (Modbus TCP protocol).
See more Zobacz produkt

USB RS-485 converter without galvanic separation. Transmission speed in the range of 300 bps to 115.2 kbps. Software to work with programs communicating over COM serial ports. Three LEDs. Power from USB only. Designed for service work.
See more Zobacz produkt

USB RS-485 converter with galvanic separation. Transmission speed in the range of 300 bps to 115.2 kbps. Software that allows you to work with programs that communicate over a serial COM. Four LEDs. Power from USB only. Shipping the same or next working day.
See more Zobacz produkt

Converter allows to connect devices with RS-485 port to industrial or LAN network. On RS-485 side may be connected up to 32 devices and on Ethernet port side converter can serve up to 6 clients. Shipping the same or next working day.
See more Zobacz produkt

20 W Single Output Industrial DIN Rail Power Supply. Can be mounted on TS-35 rail.
See more Zobacz produkt

60 W Single Output Industrial DIN Rail Power Supply. Can be mounted on TS-35 rail.
See more Zobacz produkt

Adapters allow installation of panel devices series DL5, DL7, DL2, FP70, FP30XX, FP4, FP70P on DIN mounting rail.
See more Zobacz produkt

Pendrive enabling reading of archived data, reading and saving settings from devices.
See more Zobacz produkt

    Descritpion

    Flow totalizer with data recording

    • 2 analog inputs
    • 2 PULS inputs
    • 2 math channels
    • 4-20mA analog output
    • 4 solid state relays
    • USB port on front panel
    • Ethernet port (Modbus TCP protocol, server www)
    • RS-485 port (Modbus RTU protocol)
    E-mail notifications, information about alarms, cycilc reports with totalizers value
    • 4” Touch screen LCD
    • Internal memory 2 GB

    2 ANALOG INPUTS

    Independent setup for input sensors
    •  Transducers with 4-20mA (with optional power supply from device) or 0-20mA current loop output
    •  RTD sensors (Pt100, Pt200, Pt500, Pt1000)
    •  Transducers with 0…2500 Ω resistance output
    •  Transducers with –1 V…+1 V or –10 V…+10 V voltage output

    2 PULS INPUTS

    • Frequency measurement in range 0,01 Hz … 10 kHz
    • Counting pulses
    • Tracking and recording of binary signal (shorting or disconnecting)

    ANALOG OUTPUT

    • Retransmission of one of the channels as a 4-20mA current loop output signal

    TOTALIZERS

    • For each input there are available two totalizers L1 and L2
    • Totalizers can be reset manually or they can work automatically: daily ,weekly or monthly
    • Totalizers T1 and T2 counting the operation time of totalizers
    • Frequency of archiving, for counters, from 1 min to 24h

    4 ALARM AND CONTROL SYSTEM

    • 4 solid state relays 0,1 A / 60 V
    • 2 alarm and control thresholds for each channel

    RECORDING MEASUREMENT RESULT

    • Recording data to internal 2GB memory, local access to recorded data through USB port on the front panel
    • Data recording rate between 2 s and 24 h; two recording frequencies toggled upon exceeding the set alarm thresholds

    INTENDED USE

    • Measurement of flow and other quantities, e.g. temperature, humidity, pressure
    • Operation in dispersed measurement systems with local readings of measurement results
    • Grocery, steel, metallurgical, glass-making industry, warehouse and production line control

     

    This product is CE marked.
    Declarations of Conformity are available on request.

    Technical data
    Front panel (FP4, FP4W)
    Type of display

     

    LCD TFT 4” 800 px X 480 px

    LED backlight

    Display size 86.4 mm X 52.5 mm
    Keyboard resistive touch panel
    Additional indication LED RGB
    USB Port – front panel (FP4, FP4W)
    Version USB 2.0 (with limited functionality, for connection of FLASH storage)
    Connector type USB standard ‘A’ type socket
    Files system FAT16, FAT32(1)
    (1)Compatibility of all USB memory devices is not guaranteed.
    Ethernet Port (FP4, FP4W)
    Interface 10/100Base-T Ethernet
    Connector type RJ-45
    Transmission protocol Server WWW, Modbus TCP

    ICMP (ping)

    Number of connections opened simultaneously Max 4
    RS-485 Serial Port (FP4, FP4W)
    Signals output on terminal block A(+), B(-)
    Galvanic isolation None
    Maximum load 32 receivers/transmitters
    Transmission protocol Modbus RTU Slave
    Transmission rate 1.2, 2.4, 4.8, 9.6, 19.2, 38.4, 57.6, 115.2 kbps
    Parity control Even, Odd, None
    Frame 1 start bit, 8 data bits, 1 stop bit
    Maximum length of line 1200 m
    Internal terminating resistor Vcc-A(+)-B(-)-G: 390 Ω – 220 Ω – 390 Ω

    (activated by DIP-switches)

    Maximum differntial voltage A(+), B(-) -7 .. +12 V
    Minimum output signal of transmitter 1.5 V (at RL= 54 W)
    Minimum sensitivity of receiver 200 mV / RIN= 12 kW
    Minimum impedance of data transmission line 54 W
    Short-circuit/thermal protection Yes/Yes
    Internal data memory (FP4, FP4W)
    Memory type Flash
    Capacity 2 GB
    Estimated recording time for recording speed every 2 s for 6 measuring channels ca. 2 years
    Supply (FP4)
    Supply voltage 24 VDC (20 .. 30 VDC)
    Maximum power consumption 6 W (typically 4 W)
    Security The internal delay fuse 3.15 A, the exchange only by the service company
    Supply (FP4W)
    Supply voltage 100 .. 240 VAC 50/60 Hz or 24 VDC (20 .. 30 VDC)
    Maximum power consumption ·  for 100 .. 240 VAC 50/60 Hz power supply:

    8 W (typically 6 W)

    ·  for 24 VDC (20 .. 30 VDC) power supply:

    6 W (typically 4 W)

    Security The internal delay fuse 3.15 A, the exchange only by the service company
    Output 24 V OUT (FP4W)
    Output voltage (on 24 V OUT) unregulated 18 .. 26 VDC
    Maximum load current (on 24 V OUT) 100 mA
    Electrical connections (FP4)
    Type screw terminal connectors
    Wire cross section solid and flexible 0.14 .. 1.5 mm2

    flexible with bootlace ferrule 0.25 .. 1.5 mm2

    AWG 30/14

    Electrical connections (FP4W)
    Type spring type terminal block
    Wire cross section ·  supply 230 VAC: 0.2 .. 2.5 mm2

    ·  others: 0.2 .. 1.5 mm2

    Cable glands ·  supply: one M16 cable  gland,  cable diameter:
    5 .. 10 mm·  I/O signals: three M20 cable glands, cable diameter: 8 .. 13 mm·  Ethernet: one M20 cable gland,  cable diameter: 6 mm (the possibility of installing a cable with an RJ-45 connector)
    Mechanical Dimensions – enclosure (FP4)
    Enclosure type panel mount, nonflammable plastic material „Noryl”
    Dimensions with connectors (w X h X d) 144 mm X 72 mm X 127 mm
    Dimensions of panel cut-out (w X h) 138+1 mm X 68+0.7 mm
    Maximum panel thickness 5 mm
    Weight 0.5 kg
    Protection class IP30 on front panel side

    IP30 on rear panel side

    Mechanical Dimensions – enclosure (FP4W)
    Enclosure type Wall mount, polycarbonate material
    Dimensions (w X h X d) ·  without cable glands:

    213 mm x 185 mm x 102 mm

    ·  with cable glands:

    213 mm x 215 mm x 102 mm

    Weight c.a. 0.8 kg
    Protection class IP54
    Environmental conditions (FP4, FP4W)
    Ambient temperature ·  FP4: 0 .. +50 °C

    ·  FP4W: -20 .. +50 °C

    Relative humidity 5 .. 95% (without steam condensation)
    Maximum altitude <2000 m above sea level
    Storage temperature -30 .. +70 °C
    Degree of pollution PD2
    EMC EMC Directive 2014/30/EU

    EN 61326-1:2013 Table 2 (immunity)

    EN 61326-1:2013 Class A (emission)

    RoHS RoHS Directive 2011/65/EU
    Installation location ·  FP4: Indoor only

    ·  FP4W: Indoor or outdoor(2)

    (2)If additional protection against atmospheric precipitation is provided (roofing), the device can be installed outdoor.
    ANALOGUE INPUTS (FP4, FP4W)
    Number of inputs 2 (input type (0/4-20mA/RTD/U) configurable by jumpers inside the device)
    Update rate 0.5 s/display every 1 s
    Low-pass digital filter (damping filter)(3) A time constant programmed in the range 2 .. 60 s
    Galvanic isolation between inputs None
    Galvanic isolation from the other circuits Functional, 250 VAC
    Maximum input voltage ±30 VDC between terminals A(I+), B(I-)
    Configuration: 0/4-20mA input(4)
    Measurement range 0 .. 22 mA
    Input resistance <100 Ω
    Initial accuracy (Ta=+25 °C) ±0.1% of range (typically ±0.05% of range)
    Conversion characteristic Linear or User
    Transducers powered from recorder 24 VDC (+10/-20%), 24 mA (current-limited polymer fuse)
    (4)The device is delivered in the 0/4-20mA configuration.
    Configuration: R/RTD input
    Sensor type ·  Resistive (refer the table below)

    ·  Linear resistance

    Sensor connection type 2-wire
    Sensor current 420 μA
    Wire resistance compensation in the 2-wire connection User programmed in the range of -99 .. +99 Ω
    Resistance of wires (to the sensor) max 50 Ω
    Transducer resistance range 0 .. 2700 Ω
    Initial accuracy (Ta=+25 °C) ±0.5 Ω (typically ±0.3 Ω)
    Conversion characteristic for R Linear, User or sensors
    RTD sensor type, range and accuracy Refer the table below
    Configuration: U (±10 V) input
    Voltage range -10 .. +10 V
    Input resistance >10 kΩ
    Conversion characteristic (for U) Linear or User
    Initial accuracy (Ta=+25 °C) ±0.5% of range
    PULS TYPE INPUTS (FP4, FP4W)
    Number of inputs 2
    Measurement range ·  0.01 Hz .. 10 kHz, additional filter disabled

    ·  0.01 Hz .. 1 kHz, additional filter enabled

    Minimum pulse width ·  50 μs, additional filter disabled

    ·  0.5 ms, additional filter enabled

    Maximum input voltage ±30 VDC (between terminals F+ and F-)
    Frequency measurement
    Conversion characteristic Linear or User
    Initial accuracy (Ta=+25 °C) 0.05% * f ±0.1 Hz
    Pulse counting
    Conversion characteristic Linear
    Measuring range 0 .. 10 kHz
    Initial accuracy (Ta=+25 °C) 0.05% * f ±0.1 Hz

    (without losing pulses in the counters)

    Configuration: OC/contact(5)
    Open contact voltage ca. 4.3 V
    Short circuit current ca. 4.3 mA
    Switch on/off threshold ca. 2.4 V / 2.6 V
    Maximum short circuit resistance 100 Ω
    (5)The device is delivered in the OC/contact configuration, with the additional filtering capacitor disconnected.
    Configuration: current input NAMUR
    Input resistance 1.5 kΩ
    Switch on/off threshold ca. 1.6 mA / 1.8 mA
    Configuration: current input EH
    Input resistance 200 Ω
    Switch on/off threshold ca. 11 mA / 13 mA
    Configuration: voltage input
    Input resistance >10 kΩ
    Switch on/off threshold ca. 2.4 V / 2.6 V
    Maximum input voltage ±30 VDC
    RELAY OUTPUTS (FP4, FP4W)
    Number of outputs 4
    Outputs type Solid state relays
    Maximum voltage 60 V AC/DC
    Maximum load current 0.1 A
    ANALOGUE OUTPUT 4-20mA (FP4, FP4W)
    Output signal 4-20 mA (3.6 .. 22 mA)
    Current loop supply no (external supply required)
    Maximum voltage between I+ and I- 28 VDC
    Minimum supply current loop voltage 9 VDC (RL=0 Ω)
    Loop resistance (RL) 0 .. 500 Ω
    Accuracy 0.2%
    Galvanic isolation to supply voltage Functional, 250 VAC
    Accesories

    Software for analysis, visualization and archiving of measurement results.
    See more Zobacz produkt

    Software allows you to read settings files stored by the instrument, modify settings, save to file, and program the instrument via a USB memory stick. Software also allows you to create new settings files for the instruments
    See more Zobacz produkt

    Software mLog enable reading, visualization and archiving data from devices and transducers with RS485 port (Modbus RTU protocol) or Ethernet port (Modbus TCP protocol).
    See more Zobacz produkt

    USB RS-485 converter without galvanic separation. Transmission speed in the range of 300 bps to 115.2 kbps. Software to work with programs communicating over COM serial ports. Three LEDs. Power from USB only. Designed for service work.
    See more Zobacz produkt

    USB RS-485 converter with galvanic separation. Transmission speed in the range of 300 bps to 115.2 kbps. Software that allows you to work with programs that communicate over a serial COM. Four LEDs. Power from USB only. Shipping the same or next working day.
    See more Zobacz produkt

    Converter allows to connect devices with RS-485 port to industrial or LAN network. On RS-485 side may be connected up to 32 devices and on Ethernet port side converter can serve up to 6 clients. Shipping the same or next working day.
    See more Zobacz produkt

    20 W Single Output Industrial DIN Rail Power Supply. Can be mounted on TS-35 rail.
    See more Zobacz produkt

    60 W Single Output Industrial DIN Rail Power Supply. Can be mounted on TS-35 rail.
    See more Zobacz produkt

    Adapters allow installation of panel devices series DL5, DL7, DL2, FP70, FP30XX, FP4, FP70P on DIN mounting rail.
    See more Zobacz produkt

    Pendrive enabling reading of archived data, reading and saving settings from devices.
    See more Zobacz produkt
    Ask for products